beautypg.com

Using the remote tank console to adjust settings – Seed Hawk Raven 2012 User Manual

Page 199

background image

10

Manual No. 016-3001-003

187

Remote Calibration Console

Using the Remote Tank Console to Adjust Settings

The following settings may be entered using the remote tank console. Settings will be stored in the appropriate
nodes on the Seed Hawk system and will be registered by the Viper Pro when starting the Seed Hawk
application for seeding operations.

To adjust settings for a specific bin or product:

1.

With the remote tank console powered up, use the Next and Prev keys to select the desired bin and press
the Enter key.

2.

Press the Setup key to display the current settings for the selected bin.

3.

The following settings will be available on the first settings screen:

Note:

Use the Next or Prev keys to move the cursor between the screen options. Pressing the Prev key
on the decimal shift option will return to the bin calibration screen. Press the Next key on the cal
weight option to advance to the second settings screen.

Decimal Shift. Press the Toggle key on the decimal shift option to turn the decimal shift feature on or off.

Enable the decimal shift feature to increase the system accuracy for low application rates. In the standard
mode, the remote tank console and Viper Pro field computer will display values to one decimal place. With
the Decimal Shift feature enabled, values will be displayed to two decimal places.

Note:

When the Seed Hawk Viper Pro is initialized, all of the calibration values will need to be verified
after the Decimal Shift feature is either enabled or disabled. Change settings as necessary.

Meter Cal. Press the Enter key on the meter cal option to edit the current meter cal value. The meter cal value

is the number of counts the metering roller sensor will detect per revolution of the metering roller.
Use the INC or DEC keys to adjust the meter cal value and press the Enter key to set the meter cal value.

Note:

It is recommended to enter a meter cal of 60.31 using the Seed Hawk Viper Pro console for the
hydraulic drive system.

Cal Weight. Press the Enter key on the cal weight option and use the INC or DEC keys to adjust the set cal

weight value. The cal weight value to set the cal weight sets the weight of product applied per revolution of
the metering roller.
Refer to Catch Test and Cal Weight section on page 184 for details on using the remote tank console to
calculate the cal weight value.