Low Tank. The low tank value displays an alert when the volume remaining in a tank or bin is reduced to the
entered value. When the calculated volume remaining in the tank or bin is reduced to the entered value, the
Viper Pro will display an alert.
Note:
To utilize the low tank alarm feature, an initial tank or bin volume must be entered for the
corresponding product node or control channel. Refer to Tank Volume section on page 136 for
details on setting the initial tank or bin volume.
The alarm condition is cleared either when all sections are turned off or if a new low tank value less than or
equal to the current calculated tank volume is entered. Enter a value of zero to disable the low tank alarm.
Node Settings Screen (Page 2)
From the CAN Controller Status screen, touch within the Features Settings area to display the first Node
Settings screen and select the Next button to access the following alarm and feature settings.
Note:
The following sections offer descriptions of the various options and settings used with products 4
and 5. For descriptions of the settings used with products 1 through 3, see the Feature Settings
Area for Products 1-3 section on page 125.
Zero Speed Shutoff. Enable the zero speed shutoff feature to allow the field computer to automatically shut
off product application if the vehicle speed is slower than 0.7 mph [1.1 km/h]. If the zero speed shutoff feature
is engaged during a job, the Viper Pro will also display a zero speed alert.
Note:
The zero speed shutoff feature only affects products set to automatic control. Products controlled
manually will continue to be applied even if the zero speed shutoff feature is engaged.
To restart product application after the zero speed shutoff feature has engaged, cycle the master switch ‘Off’
and then back ‘On.’ The zero speed shutoff feature will reactivate if the vehicle does not achieve a speed
greater than 0.7 MPH [1.1 km/h] and maintain that speed for more than 10 seconds.
Note:
If an optional SCT system is connected, the SCT override may be enabled to begin product
application from a complete stop. Refer to the Enabling Sectional Control Override section on
page 168 for more information.