Tab. 6.3, Options for ping for multiple ip addresses – Siemens S223 User Manual
Page 96
UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
96 A50010-Y3-C150-2-7619
The following is the information to use ping test for multiple IP addresses.
Items Description
Source address or interface
Designates the address where the relative device should respond in
source ip address.
Type of service [0]:
The service filed of QoS (Quality Of Service) in Layer 3 application. It
is possible to designate the priority for IP Packet.
Set DF bit in IP header? [no]
Decides whether Don’t Fragment (DB) bit is applied to Ping packet or
not. Default is no. If the user choose ‘yes’, when the packets pass
through the segment compromised with the smaller data unit, it pre-
vents the packet to be Fragment. Therefore there could be error mes-
sage.
Data pattern [0xABCD]
Configures data pattern. Default is OxABCD.
Tab. 6.3
Options for Ping for Multiple IP Addresses
The following is to verify network status between 172.16.157.100 and 172.16.1.254 when
IP address of the switch is configured as 172.16.157.100.
SWITCH# ping
Protocol [ip]:
Target IP address: 172.16.1.254
Repeat count [5]: 5
Datagram size [100]: 100
Timeout in seconds [2]: 2
Extended commands [n]: y
Source address or interface: 172.16.157.100
Type of service [0]: 0
Set DF bit in IP header? [no]: no
Data pattern [0xABCD]:
PATTERN: 0xabcd
PING 172.16.1.254 (172.16.1.254) from 172.16.157.100 : 100(128) bytes of data.
108 bytes from 172.16.1.254: icmp_seq=1 ttl=255 time=30.4 ms
108 bytes from 172.16.1.254: icmp_seq=2 ttl=255 time=11.9 ms
108 bytes from 172.16.1.254: icmp_seq=3 ttl=255 time=21.9 ms
108 bytes from 172.16.1.254: icmp_seq=4 ttl=255 time=11.9 ms
108 bytes from 172.16.1.254: icmp_seq=5 ttl=255 time=30.1 ms
--- 172.16.1.254 ping statistics ---
5 packets transmitted, 5 received, 0% packet loss, time 8050ms
rtt min/avg/max/mdev = 11.972/21.301/30.411/8.200 ms
SWITCH#