beautypg.com

Fig. 5.2, Port mirroring – Siemens S223 User Manual

Page 81

background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 81

Fig. 5.2

Port Mirroring

To configure port mirroring, designate mirrored ports and monitor port. Then enable port
mirroring function. Monitor port should be connected to the watch program installed PC.
You can designate only one monitor port but many mirrored ports for one switch.

Step 1

Activate the port mirroring, using the following command.

Command Mode

Description

mirror enable

Bridge

Activates port mirroring.

Step 2

Designate the monitor port, use the following command.

Command Mode

Description

mirror monitor

{PORTS I cpu}

Bridge

Designates the monitor port.

Step 3

Designate the mirrored ports, use the following command.

Command Mode

Description

mirror add

PORTS [ingress |

egress

]

Bridge

Designates the mirrored ports.
ingress: ingress traffic
egress: egress traffic

This manual is related to the following products: