Fig. 5.2
Port Mirroring
To configure port mirroring, designate mirrored ports and monitor port. Then enable port
mirroring function. Monitor port should be connected to the watch program installed PC.
You can designate only one monitor port but many mirrored ports for one switch.
Step 1
Activate the port mirroring, using the following command.
Command Mode
Description
mirror enable
Bridge
Activates port mirroring.
Step 2
Designate the monitor port, use the following command.
Command Mode
Description
mirror monitor
{PORTS I cpu}
Bridge
Designates the monitor port.
Step 3
Designate the mirrored ports, use the following command.
Command Mode
Description
mirror add
PORTS [ingress |
egress
]
Bridge
Designates the mirrored ports.
ingress: ingress traffic