7.1.9.4 Generic
Alarm
Severity
To configure generic alarm severity, use the following command.
Command Mode
Description
snmp alarm-severity fan-fail
{critical | major |
minor
| warning | intermediate}
Configures the priority of fan-fail alarm
snmp alarm-severity cold-start
{critical | major
| minor | warning | intermediate}
Configures the priority of cold-start
alarm
snmp alarm-severity broadcast-over
{critical |
major
| minor | warning | intermediate}
Configures the priority of broadcast-
over alarm
snmp alarm-severity cpu-load-over
{critical |
major
| minor | warning | intermediate}
Configures the priority of cpu-load-over
alarm
snmp alarm-severity dhcp-lease
{critical | ma-
jor
| minor | warning | intermediate}
Configures the priority of DHCP-lease
alarm
snmp alarm-severity dhcp-illegal
{critical |
major
| minor | warning | intermediate}
Configures the priority of DHCP-illegal
alarm
snmp alarm-severity fan-remove
{critical |
major
| minor | warning | intermediate}
Configures the priority of fan-remove
alarm
snmp alarm-severity ipconflict
{critical | major
| minor | warning | intermediate}
Configures the priority of IP conflict
alarm
snmp alarm-severity memory-over
{critical |
major
| minor | warning | intermediate}
Configures the priority of memory-over
alarm
snmp alarm-severity mfgd-block
{critical |
major
| minor | warning | intermediate}
Configures the priority of MFGD-block
alarm
snmp alarm-severity port-link-down
{critical |
major
| minor | warning | intermediate}
Configures the priority of port-link-down
alarm
snmp alarm-severity port-remove
{critical |
major
| minor | warning | intermediate}
Configures the priority of port-remove
alarm
snmp alarm-severity port-thread-over
{critical |
major
| minor | warning | intermediate}
Configures the priority of port-thread-
over alarm.
snmp alarm-severity power-fail
{critical | major
| minor | warning | intermediate}
Configures the priority of power-fail
alarm
snmp alarm-severity power-remove
{critical |
major
| minor | warning | intermediate}
Configures the priority of power-remove
alarm
snmp alarm-severity rmon-alarm-rising
{criti-
cal
| major | minor | warning | intermediate}
Configures the priority of RMON-alarm-
rising alarm.
snmp alarm-severity rmon-alarm-falling
{criti-
cal
| major | minor | warning | intermediate}
Configures the priority of RMON-alarm-
falling alarm.
snmp alarm-severity system-restart
{critical |
major
| minor | warning | intermediate}
Configures the priority of system-restart
alarm.
snmp alarm-severity module-remove
{critical |
major
| minor | warning | intermediate}
Configures the priority of module-
remove alarm.
snmp alarm-severity temperature-high
{critical
| major | minor | warning | intermediate}
Global
Configures the priority of temperature-
high alarm.