beautypg.com

6 erp alarm severity – Siemens S223 User Manual

Page 116

background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

116 A50010-Y3-C150-2-7619

Command Mode

Description

snmp alarm-severity adva-if-trans-fault

{criti-

cal

| major | minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs to fail to transmit
the packets.

snmp alarm-severity adva-psu-fail

{critical |

major

| minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs there’s any
problem on the power.

snmp alarm-severity adva-temperature

{critical

| major | minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs there is any
problem in temperature.

snmp alarm-severity adva-voltage-high

{criti-

cal

| major | minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs the voltage is
high.

snmp alarm-severity adva-voltage-low

{critical

| major | minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs the voltage is
low.

If you want to clear a configured ADVA alarm prioirity, use the following command.

Command Mode

Description

no snmp alarm-severity adva-fan-fail

no snmp alarm-severity adva-if-misconfig

no snmp alarm-severity adva-if-opt-thres

no snmp alarm-severity adva-if-rcv-fail

no snmp alarm-severity adva-if-sfp-mismatch

no snmp alarm-severity adva-if-trans-fault

no snmp alarm-severity adva-psu-fail

no snmp alarm-severity adva-temperature

no snmp alarm-severity adva-voltage-high

no snmp alarm-severity adva-voltage-low

Global

Clears a configured ADVA alarm
prioirity.

7.1.9.6 ERP

Alarm

Severity

To configure a severity of alarms for ERP status, use the following command.

Command Mode

Description

snmp alarm-severity erp-domain-lotp

{critical |

major

| minor | warning | intermediate}

Sends alarm notification with the sever-
ity when no test packet has been re-
ceived within 3 test packet intervals in
ERP mechanism.

snmp alarm-severity erp-domain-multi-rm

{critical | major | minor | warning | intermedi-

ate

}

Global

Sends alarm notification with the sever-
ity when a Multiple RM node is created.

This manual is related to the following products: