beautypg.com

5 limiting number of user, 6 telnet access, Limiting number of user – Siemens S223 User Manual

Page 47: Telnet access

background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 47

leged EXEC Enable

mode; however as level 1, it is possible to use not only the com-

mands in level 1 but also time configuration commands in Privileged EXEC Enable mode
and accessing commands to Global Configuration mode.

4.1.5

Limiting Number of User

For hiD 6615 S223/S323, you can limit the number of user accessing the switch through
both console port and telnet. In case of using the system authentication with RADIUS or
TACACS+, the configured number includes the number of user accessing the switch via
the authentication server.

To set the number of user accessing the switch, use the following command.

Command Mode

Description

login connect

<1-8>

Global

Sets the number of user accessing the switch.
Default: 8

4.1.6 Telnet

Access

To connect to the host through telnet at remote place, use the following command.

Command Mode

Description

telnet DESTINATION

[TCP-PORT]

Enable

Connects to a remote host.
DESTINATION: IP address or host name

In case of telnet connection, you should wait for [OK] message, when you save a system
configuration. Otherwise, all changes will be deleted when the telnet session is discon-
nected.

SWITCH# write memory

[OK]

SWITCH#

The system administrator can disconnect users connected from remote place. To discon-
nect a user connected through telnet, use the following command.

Command Mode

Description

disconnect

TTY-NUMBER

Enable

Disconnects a user connected through telnet.

The following is an example of disconnecting a user connected from a remote place.

SWITCH# where

admin at from console for 4 days 22 hours 15 minutes 24.88 seconds

admin at ttyp0 from 10.0.1.4:1670 for 4 days 17 hours 53 minutes 28.76 seconds

admin at ttyp1 from 147.54.140.133:49538 for 6 minutes 34.12 seconds

SWITCH# disconnect ttyp0

SWITCH# where

admin at from console for 4 days 22 hours 15 minutes 34.88 seconds

admin at ttyp1 from 147.54.140.133:49538 for 6 minutes 44.12 seconds

SWITCH#

!