beautypg.com

6 manual switch to secondary, 7 wait-to-restore time, 8 learning disable time – Siemens S223 User Manual

Page 269: 9 test packet interval

background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 269

8.9.3.6

Manual Switch to Secondary

To configure Manual Switch to Secondary, use the following command.

Command Mode

Description

erp ms-s DOMAIN-ID

Bridge

Configures ERP manual switch to secondary

To disable Manual Switch to Secondary, use the following command.

Command Mode

Description

no erp ms-s

DOMAIN-ID

Bridge

Disables ERP manual switch to secondary

8.9.3.7 Wait-to-Restore

Time

To configure Wait-to-Restore Time, use the following command.

Command Mode

Description

erp wait-to-restore

DOMAIN-ID

<1-720>

Bridge

Configures ERP wait-to-restore time
1-720: Wait to restore time in second

To return the configured Wait-to-Restore Time as Default, use the following command.

Command Mode

Description

no erp wait-to-restore

DOMAIN-

ID

Bridge

Configures ERP wait-to-restore time as default value

8.9.3.8

Learning Disable Time

To configure ERP Learning Disable Time, use the following command.

Command Mode

Description

erp learn-dis-time

DOMAIN-ID

<0-500>

Bridge

Configures ERP learning disable time
0-500: learning disabling time (unit: millisecond)

To return the configured Learning Disable Time as Default, use the following command.

Command Mode

Description

no erp learn-dis-time

DOMAIN-ID

Bridge

Configures ERP learning disable time as default value

8.9.3.9

Test Packet Interval

To configure ERP Test Packet Interval, use the following command.

Command Mode

Description

erp test-packet-interval

DO-

MAIN-ID

<10-500>

Bridge

Configures ERP test packet interval
10-500: packet interval (unit: millisecond)

This manual is related to the following products: