beautypg.com

3 igmp v2 snooping last-member-interval – Siemens S223 User Manual

Page 293

background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 293

To display IGMP query parameter, use the following command.

Command Mode

Description

show ip igmp snooping

[vlan

VLANS

] querier [detail]

Enable

Global
Bridge

Verifies that the IGMP snooping querier is enabled.

9.2.5.3

IGMP v2 Snooping Last-Member-Interval

When receive Leave Message from host in IGMP v2, Querier sends Specific Query and
check whether there is Multicast Group Member. Basically, if Membership Report about
First Specific Query does not come, after 1 second, send second Specific Query. If there
is no response also, it deleted from Membership Table. Last-member-interval is the value
to regulate gap between first Specific Query and second Specific Query. By limiting Inter-
val value, IGMP v2 function and fast Leave can be implemented.

To send IGMP Query message and configure the respond time, use the following com-
mand.

Command Mode

Description

ip igmp snooping last-member-

query-interval

<100-10000>

Configures the time of registering in multicast group
after sending Join message on the system. (unit: ms)

ip igmp snooping vlan

VLANS

last-member-query-interval

<100-10000>

Global

Configures the time of registering in multicast group
after sending Join message on a VLAN interface.

If you configure ip igmp snooping fast-leave, it is meaningless to register time as multi-
cast group.

To release the waiting time for respond after sending IGMP Query message, use the fol-
lowing command.

Command Mode

Description

no ip igmp snooping last-

member-query-interval

Returns to the default time of registering Join message
in multicast group after sending it.

no ip igmp snooping vlan

VLANS

last-member-query-

interval

Global

Returns to the default time of registering Join message
after sending it on a VLAN interface.