If you want to delete a configured alarm severity, use the following command.

Command Mode

Description

no snmp alarm-severity fan-fail

no snmp alarm-severity cold-start

no snmp alarm-severity broadcast-over

no snmp alarm-severity cpu-load-over

no snmp alarm-severity dhcp-lease

no snmp alarm-severity dhcp-illegal

no snmp alarm-severity fan-remove

no snmp alarm-severity ipconflict

no snmp alarm-severity memory-over

no snmp alarm-severity mfgd-block

no snmp alarm-severity port-link-down

no snmp alarm-severity port-remove

no snmp alarm-severity port-thread-over

no snmp alarm-severity power-fail

no snmp alarm-severity power-remove

no snmp alarm-severity rmon-alarm-rising

no snmp alarm-severity rmon-alarm-falling

no snmp alarm-severity system-restart

no snmp alarm-severity module-remove

no snmp alarm-severity temperature-high

Global

Deletes a configured alarm severity.

7.1.9.5 ADVA

Alarm

Severity

To configure a severity of alarms for ADVA status, use the following command.

Command Mode

Description

snmp alarm-severity adva-fan-fail

{critical |

major

| minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs fan-fail.

snmp alarm-severity adva-if-misconfig

{critical

| major | minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs there’s any mis-
configuration.

snmp alarm-severity adva-if-opt-thres

{critical |

major

| minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs traffic is over
threshold on optical interface.

snmp alarm-severity adva-if-rcv-fai

l {critical |

major

| minor | warning | intermediate}

Sends alarm notification with the sever-
ity when ADVA informs to fail to receive
the packets.

snmp alarm-severity adva-if-sfp-mismatch

{critical | major | minor | warning | intermedi-

ate

}

Global

Sends alarm notification with the sever-
ity when ADVA informs SFP module is
mismatched.