4 lldp message, 5 interval and delay time, Lldp message – Siemens S223 User Manual
Page 124: Interval and delay time
UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
124 A50010-Y3-C150-2-7619
In hiD 6615 S223/S323, the administrator can enable and disable basic TLV by selecting
it. To enable basic TLV by selecting it, use the following command.
Command Mode
Description
lldp
enable PORTS {portdescrip-
tion
| sysname | sysdescription |
syscap
}
Selects basic TLV that is sent in the port.
portdescription: Port’s description
syscap: System’s capablility
sysname: System’s name
sysdescription: System’s description
lldp
disable PORTS {portde-
scription
| sysname | sysde-
scription
| syscap}
Bridge
Disables basic TLV configured as sent in the port.
7.3.4 LLDP
Message
In hiD 6615 S223/S323, it is possible to configure the interval time and times of sending
LLDP message. To configure the interval time and times of LLDP message, use the fol-
lowing command.
Command Mode
Description
lldp msg txinterval
<5-32768>
Configures the interval of sending LLDP message. The
unit is second.
lldp msg txhold
<2-10>
Bridge
Configures the periodic times of LLDP message.
Default for sending LLDP message is 4 times in every 30 seconds.
7.3.5
Interval and Delay Time
In hiD 6615 S223/S323, the administrator can configure the interval time of enabling
LLDP frame after configuring LLDP operation type. To configure the interval time of ena-
bling LLDP frame after configuring LLDP operation type, use the following command.
Command Mode
Description
lldp reinitdelay
<1-10>
Bridge
Configures the interval time of enabling LLDP frame
from the time of configuring not to process LLDP
frame. (default: 2)
To configure delay time of transmitting LLDP frame, use the following command.
Command Mode
Description
lldp txdelay
<1-8192>
Bridge
Configures delay time of transmitting LLDP frame.
(default: 2)
i