1 source port of statistical data, 2 subject of rmon history, 3 number of sample data – Siemens S223 User Manual
Page 127: 4 interval of sample inquiry
User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 127
want to list available commands.
The following is an example of listing available commands on RMON Configuration mode.
SWITCH(config-rmonhistory[5])# ?
RMON history configuration commands:
active
Activate the history
data-source
Set data source port
do
To run exec commands in config mode
exit
End current mode and down to previous mode
help
Description of the interactive help system
interval
Define the time interval for the history
owner
Assign the owner who define and is using the history
resources
requested-buckets
Define the bucket count for the interval
show
Show running system information
SWITCH(config-rmonhistory[5])#
7.4.1.1
Source Port of Statistical Data
To specify a source port of statistical data, use the following command.
Command Mode
Description
data-source
NAME RMON
Specifies a data object ID.
NAME: enters a data object ID. (ex. ifindex.n1/port1)
7.4.1.2
Subject of RMON History
To identify subject using RMON history, use the following command.
Command Mode
Description
owner
NAME RMON
Identifies subject using related data, enter the name
(max. 32 characters).
7.4.1.3
Number of Sample Data
To configure the number of sample data of RMON history, use the following command.
Command Mode
Description
requested-buckets
<1-65535>
RMON
Defines a bucket count for the interval, enter the num-
ber of buckets.
1-65535: bucket number (default: 50)
7.4.1.4
Interval of Sample Inquiry
To configure the interval of sample inquiry in terms of second, use the following command.
Command Mode
Description
interval
<1-3600>
RMON
Defines the time interval for the history (in seconds),
enter the value. (default: 1800)