beautypg.com

3 enabling snmp trap – Siemens S223 User Manual

Page 110

background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

110 A50010-Y3-C150-2-7619

7.1.8.3

Enabling SNMP Trap

The system provides various kind of SNMP trap, but it may inefficiently work if all these
trap messages are sent very frequently. Therefore, you can select each SNMP trap sent
to an SNMP trap host.

The system is configured to send all the SNMP traps as default.

authentication-failure

is shown to inform wrong community is input when user trying

to access to SNMP inputs wrong community.

cold-start

is shown when SNMP agent is turned off and restarts again.

link-up/down

is shown when network of port specified by user is disconnected, or

when the network is connected again.

memory-threshold

is shown when memory usage exceeds the threshold specified

by user. Also, when memory usage falls below the threshold, trap message will be

shown to notify it.

cpu-threshold

is shown when CPU utilization exceeds the threshold specified by

user. Also, when CPU load falls below the threshold, trap message will be shown to

notify

it.

port-threshold

is shown when the port traffic exceeds the threshold configured by

user. Also, when port traffic falls below the threshold, trap message will be shown.

temperature-threshold

is shown when the system temperature exceeds the thresh-

old configured by user. Also, when system temperature falls below the threshold, trap

message will be shown.

dhcp-lease

is shown when there is no more IP address can be assigned in subnet of

DHCP server. Even if only one subnet does not have IP address to assign when

there are several subnets, this trap message will be seen.

fan/power/module

is shown when there is any status-change of fan, power, and

module.

To enable SNMP trap, use the following command.

Command Mode

Description

snmp trap auth-fail

Configures the system to send SNMP trap when SNMP
authentication is fail.

snmp trap cold-start

Configures the system to send SNMP trap when SNMP
agent restarts.

snmp trap link-up

PORTS

[NODE]

Configures the system to send SNMP trap when a port
is connected to network.

snmp trap link-down

PORTS

[NODE]

Configures the system to send SNMP trap when a port
is disconnected from network.

snmp trap cpu-threshold

Configures the system to send SNMP trap when CPU
load exceeds or falls below the threshold.

snmp trap port-threshold

Configures the system to send SNMP trap when the
port traffic exceeds or falls below the threshold.

snmp trap temp-threshold

Global

Configures the system to send SNMP trap when sys-
tem temperature exceeds or falls below the threshold.

Command Mode

Description

i

This manual is related to the following products: