beautypg.com

4 radius server, 1 radius server for system authentication, 2 radius server priority – Siemens S223 User Manual

Page 51: 3 timeout of authentication request, Radius server

background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 51

4.2.4 RADIUS

Server

4.2.4.1

RADIUS Server for System Authentication

To add/delete the RADIUS server for system authentication, use the following command.

Command Mode

Description

login

radius server A.B.C.D

KEY

Adds the RADIUS server with its information.
A.B.C.D: RADIUS server address
KEY: authentication key value

login

radius server A.B.C.D

KEY

auth_port PORT acct_port

PORT

Adds the RADIUS server with its information.
A.B.C.D: RADIUS server address
KEY: authentication key value
auth_port: Enters authentication port number(optional)
acct_port: Enters accounting port number(optional)

no login

radius server A.B.C.D

Global

Deletes an added RADIUS server.

You can add up to 5 RADIUS servers.

4.2.4.2

RADIUS Server Priority

To specify the priority of a registered RADIUS server, use the following command.

Command Mode

Description

login radius server move

A.B.C.D

<1-5>

Global

Specifies the priority of RADIUS server.
A.B.C.D: IP address
1-5: priority of RADIUS server

4.2.4.3

Timeout of Authentication Request

After the authentication request, the hiD 6615 S223/S323 waits for the response from the
RADIUS server for specified time.

To specify a timeout value, use the following command.

Command Mode

Description

login

radius timeout <1-100>

Global

Specifies a timeout value.
1-100: waiting-time for the response (default: 3)