beautypg.com

3 filters of neighbor in pim, 4 pim hello query – Siemens S223 User Manual

Page 306

background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

306 A50010-Y3-C150-2-7619

the DR.

9.3.1.3

Filters of Neighbor in PIM

Enable filtering of neighbors on the interface. When configuring a neighbor filter-PIM-SM
will either not establish adjacency with the neighbor, or terminate adjacency with the ex-
isting neighbors-if denied by filtering access list.

To configure the filtering of neighbor in PIM, use the following command.

Command Mode

Description

ip pim neighbor-filter

{<1-99> |

ACCESS-LIST

}

Configures the filtering of neighbor in PIM.
1-99: simple access list
ACESS-LIST: IP named standard access list

no ip pim neighbor-filter

{<1-99>

| ACCESS-LIST}

Interface

Disables the filtering configuration.

9.3.1.4 PIM

Hello

Query

To configure a query hold time, use the following command.

Command Mode

Description

ip pim query-holdtime

<1-65535>

Configures the query hold time.
1-65535: hello message hold time (unit: second)

no ip pim query-holdtime

Interface

Disables the query hold time configuration.

When configuring query hold time, if the configured value is less than the current query
interval, it is refused.

To configure the frequency of hello interval value, use the following command.

Command Mode

Description

ip pim query-interval

<1-18724>

Configures the frequency of hello time.
1-18724: hello message interval (unit: second)

no ip pim query-interval

Interface

Disables the hello message interval configuration.

This manual is related to the following products: