4 associating dhcp class, 5 range of ip address for dhcp class – Siemens S223 User Manual
Page 248
UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
248 A50010-Y3-C150-2-7619
To delete specified option 82 information for IP assignment, use the following command.
Command Mode
Description
no relay-information remote-id ip
A.B.C.D [cir-
cuit-id
{hex HEXSTRING | index <0-65535> |
text
STRING}]
no relay-information remote-id hex
HEX-
STRING
[circuit-id {hex HEXSTRING | index <0-
65535> | text STRING}]
no relay-information
remote-id text STRING
[circuit-id {hex HEXSTRING | index <0-65535> |
text
STRING}]
DHCP
Class
Deletes specified option 82 information
for IP assignment.
To delete specified option 82 information for IP assignment, use the following command.
Command Mode
Description
no relay-information remote-id all
Deletes all specified option 82 informa-
tion that contains only a remote ID.
no relay-information all
DHCP
Class
Deletes all specified option 82 informa-
tion.
8.8.2.4
Associating DHCP Class
To associate a DHCP class with a current DHCP pool, use the following command.
Command Mode
Description
class CLASS
Associates a DHCP class with a DHCP pool and opens
DHCP Pool Class Configuration
mode.
CLASS: DHCP class name
no class
[CLASS]
DHCP Pool
Releases an associated DHCP class from a current
DHCP pool.
8.8.2.5
Range of IP Address for DHCP Class
To specify a range of IP addresses for a DHCP class, use the following command.
Command Mode
Description
address range
A.B.C.D A.B.C.D
Specifies a range of IP addresses.
A.B.C.D: start/end IP address
no address range
A.B.C.D
A.B.C.D
DHCP Pool
Class
Deletes a specified range of IP addresses.
A range of IP addresses specified with the address range command is valid only for a
current DHCP pool. Even if you associate the DHCP class with another DHCP pool, the