7.4.2 RMON
Alarm
There are two ways to compare with the threshold: absolute comparison and delta com-
parison.
•
Absolute Comparison
: Comparing sample data with the threshold at configured in-
terval, if the data is more than the threshold or less than it, alarm is occurred
•
Delta Comparison
: Comparing difference between current data and the latest data
with the threshold, if the data is more than the threshold or less than it, alarm is oc-
curred.
You need to open RMON Alarm Configuration mode first to configure RMON alarm.
Command Mode
Description
rmon-alarm
<1-65535>
Global
Opens RMON Alarm Configuration mode.
1-65535: index number
The following is an example of listing available commands on RMON-alarm Configuration
mode.
SWITCH(config)# rmon-alarm 1
SWITCH(config-rmonalarm[1])# ?
RMON alarm configuration commands:
active
Activate the event
do
To run exec commands in config mode
exit
End current mode and down to previous mode
falling-event
Associate the falling threshold with an existing RMON
event
falling-threshold
Define the falling threshold
help
Description of the interactive help system
owner
Assign the owner who define and is using the history
resources
rising-event
Associate the rising threshold with an existing RMON
event
rising-threshold
Define the rising threshold
sample-interval
Specify the sampling interval for RMON alarm
sample-type
Define the sampling type
sample-variable
Define the MIB Object for sample variable
show
Show running system information
startup-type
Define startup alarm type (default : rising)
write
Write running configuration to memory or terminal
SWITCH(config-rmonalarm[1])#
7.4.2.1
Subject of RMON Alarm
User needs to configure RMON alarm and identify subject using many kinds of data from
alarm. To identify subject of alarm, use the following command.
Command Mode
Description
owner
NAME RMON
Identifies subject using related data, enter the name
(max. 32 characters).