background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

82 A50010-Y3-C150-2-7619

Step 4

To delete and modify the configuration, use the following command.

Command Mode

Description

mirror disable

Deactivate monitoring.

mirror del

PORTS [ingress |

egress

]

Bridge

Delete a port from the mirrored ports.

Step 5

To disable monitoring function, use the following command.

Command Mode

Description

no mirror monitor

Bridge

Disable port mirroring function.

The following is an example of configuring port mirroring with a port.

Step 1

Connect a motoring PC to the monitor port of the switch.

Step 2

Enable mirroring function.

SWITCH(bridge)# mirror enable

SWITCH(bridge)#

Step 3

Configure the monitor port 1 and mirroring port 2, 3, 4 and 5.

SWITCH(bridge)# mirror monitor 1

SWITCH(bridge)# mirror add 2

SWITCH(bridge)# mirror add 3-5

SWITCH(bridge)#

Step 4

Check the configuration.

SWITCH(bridge)# show mirror

Mirroring enabled

Monitor port =

-----------------------------------

| 1

|123456789012

-----------------------------------

Ingress Mirrored Ports|............

Egress Mirrored Ports|............

SWITCH(bridge)#