2 default alarm severity, 3 alarm severity criterion – Siemens S223 User Manual
Page 113
User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 113
7.1.9.2 Default
Alarm
Severity
To configure a priority of alarm, use the following command.
Command Mode
Description
snmp alarm-severity default
{critical | major | minor | warning
| intermediate}
Global
Configures the priority of alarm.
(default: minor)
7.1.9.3 Alarm
Severity
Criterion
You can set an alarm severity criterion to make an alarm be shown only in case of se-
lected severity or higher. For example, if an alarm severity criterion has been set to major,
you will see only an alarm whose severity is major or critical.
To configure alarm-severity criteria in CLI, use the following command.
Command Mode
Description
snmp alarm-severity criteria
{critical | major | minor | warning
| intermediate}
Global
Configures the severity criterion.
(default: warning)
The order of alarm severity is critical > major > minor > warning > intermediate.
The alarm severity option is valid only in ACI-E.
i
!