PLCopenPlus Function Blocks for Motion Control 2013-04-13
336
4627
InvalidInput
The input reference does not correspond to real input
4628
InvalidOutput
The output reference does not correspond to a real
output
4629
InvalidIONumber
The input/output number does not correspond to a
real input or output bit
4630
InvalidTrigger
Trigger or pattern reference is not valid
4631
InvalidCamSwitch
The cam switch structure in not valid
4632
InvalidCamSwitch
The track structure is not valid
4633
InvalidTableSize
Table size results in misaligned data. Refer to the help
section “Internally Created Cam Data.” A cam table
will have a multiple of 16 bytes if created correctly.
4634
InvalidBufferSize
Buffer size results in misaligned data
4635
UnsupportedTableType
Table type is not supported
4636
InvalidStartIndex
Invalid start index.
4637
InvalidEndIndex
Invalid end index
4638
BufferOverrun
User Buffer Full.
Invalid Enumeration Type Errors
4640
InvalidEnumerationType
RESERVED
4641
InvalidBufferMode
Buffer mode does not correspond to a valid
enumeration value.
4642
InvalidDirection
Direction does not correspond to a valid enumeration
value.
4643
InvalidStartMode
Start mode does not correspond to a valid
enumeration value.
4644
InvalidShiftMode
Invalid shift mode.
4645
InvalidOffsetMode
Offset mode does not correspond to a valid
enumeration value.
4646
InvalidMode
Mode does not correspond to a valid enumeration
value.
4647
InvalidSynchMode
The synch mode does not correspond to a valid
enumeration value.
4648
InvalidParameter
The parameter number does not exist for the specified
axis
4649
InvalidAdjustMode
Invalid adjust mode
4650
InvalidRampInType
'RampIn' does not correspond to a valid enumeration
value.
4651
InvalidControlMode
'ControlMode' does not correspond to a valid
enumeration value.
4652
InvalidEndMode
Y_CamOut only supports "AtPosition"