Function block errorid list, Errorid – Yaskawa MotionWorks IEC User Manual
Page 341

PLCopenPlus Function Blocks for Motion Control 2013-04-13
333
Function Block ErrorID List
ErrorID
Name
Description
0
NoError
No Error
1
TimeLimitExceeded
Time limit exceeded.
2
DistanceLimitExceeded
Distance limit exceeded.
3
TorqueLimitExceeded
Torque limit exceeded.
Motion State Errors
4368
MotionError
General motion error
4369
MotionQueueFull
The move could not be buffered because the axis
motion queue is full. 16 moves is the maximum which
can be buffered.
4370
MotionProhibited
The move could not be started because motion is
prohibited. MC_Stop.Execute might be held high,
preventing motion. If MC_Stop has control of the axis,
no other function block can override the "Stopping"
state. Other blocks that try to cause motion while
MC_Stop has control of the axis will generate this
error. Also verify that the limit switches are not active
by checking the Global Variables for the axis.Also, a
motion block may be attempting to abort an
MC_TorqueControl move.
4371
EnabledFailed
The servo drive failed to enable or disable. Check the
amplifier wiring for L1 / L2 / L3. The amplifier could
be e-stopped or have an alarm.
4372
Drive parameter read/write did not
complete.
Drive parameter read/write did not complete.
4373
Drive parameter read/write failed.
Drive parameter read/write failed
4374
TorqueMoveProhibited
Torque move prohibited while non-torque moves
queued or in progress.
4375
NoCamForCamOut
CamOut called while not camming.
4376
MasterNotSet
The master slave relationship can not be modified
because the master axis has not been set yet.
4377
CamTableSelectInProgress
File reading already in progress
4378
InvalidAxis
The function block is not applicable for the external
axis specified
4379
HomingSequenceInProgress
A homing sequence is already in progress.
4380
SetPositionWhileMoving
MC_SetPosition can not be executed while the axis is