PLCopenPlus Function Blocks for Motion Control 2013-04-13
305
until the alarm condition is cleared.
motionKernel
3202
0005
Axis Coordinate System: The command acceleration was
greater than the allowable range for the axis in the
positive direction. The axis may not be moved again until
the alarm condition is cleared.
motionKernel
3202
0006
Axis Coordinate System: The command acceleration was
greater than the allowable range for the axis in the
negative direction. The axis may not be moved again until
the alarm condition is cleared.
motionKernel
3202
0007
Axis Coordinate System: The command torque was
greater than the allowable range for the axis in the
positive direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.
motionKernel
3202
0008
Axis Coordinate System: The command torque was
greater than the allowable range for the axis in the
negative direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.
motionKernel
3202
0011
Joint Coordinate System: The command position was
outside the allowable range for the axis in the positive
direction (positive overtravel). The axis may not be moved
again until the alarm condition is cleared. After the alarm
is cleared, it is permissible to execute a move which
brings the axis back toward the allowed region, even
though the axis is probably still outside the allowed
region. Any move which pulls the axis further away from
the allowed region will re-trigger the alarm.
motionKernel
3202
0012
Joint Coordinate System: The command position was
outside the allowable range for the axis in the negative
direction (negative overtravel). The axis may not be
moved again until the alarm condition is cleared. After the
alarm is cleared, it is permissible to execute a move which
brings the axis back toward the allowed region, even
though the axis is probably still outside the allowed
region. Any move which pulls the axis further away from
the allowed region will re-trigger the alarm.
motionKernel
3202
0013
Joint Coordinate System: The command speed was
greater than the allowable range for the axis in the
positive direction (overspeed). The axis may not be
moved again until the alarm condition is cleared.
motionKernel
3202
0014
Joint Coordinate System: The command speed was
greater than the allowable range for the axis in the
negative direction (overspeed). The axis may not be
moved again until the alarm condition is cleared.