PLCopenPlus Function Blocks for Motion Control 2013-04-13
177
Parameters
Parameter
Data type
Description
VAR_IN_OUT
B
Axis
Logical axis reference. This value can be located on the
Configuration tab in the Hardware Configuration (logical axis
number).
E
TriggerInput
TRIGGER_REF
Reference to the trigger signal source.
VAR_INPUT
Default
B
Execute
BOOL
Upon the rising edge, all other function
block inputs are read and the function is
initiated. To modify an input, change the
value and re-trigger the execute input.
FALSE
E
WindowOnly
BOOL
This feature is not currently supported.
FALSE
E
FirstPosition
LREAL
This feature is not currently supported.
LREAL#0.0
E
LastPosition
LREAL
This feature is not currently supported.
LREAL#0.0
VAR_OUTPUT
B
Done
BOOL
Set high when the commanded action has been completed
successfully. If another block takes control before the action is
completed, the Done output will not be set. This output is
reset when execute goes low.
B
Busy
BOOL
Set high upon the rising edge of the 'Execute' or 'Enable'
input, and reset if Done, CommandAborted, or Error is true.
E
CommandAborted
BOOL
Set high if motion is aborted by another motion command or
MC_Stop. This output is cleared with the same behavior as the
Done output.
B
Error
BOOL
Set high if error has occurred during the execution of the
function block. This output is cleared when 'Execute' or
'Enable' goes low.
E
ErrorID
UINT
If error is true, this output provides the Error ID. This output is
reset when 'Execute' or 'Enable' goes low.
B
RecordedPosition
LREAL
Position where trigger event occurred (in user units [u])
Notes
1. RecordedPosition will reflect the configuration of the axis, meaning that
if the axis is configured as rotary type (cyclic) then the RecordedPosition
will be modularized to fit within the Machine Cycle. To use the
unmodularized latch on an axis configured for rotary mode, use