PLCopenPlus Function Blocks for Motion Control 2013-04-13
307
greater than the allowable range for the axis in the
positive direction. The axis may not be moved again until
the alarm condition is cleared.
motionKernel
3202
0026
World Coordinate System: The command acceleration was
greater than the allowable range for the axis in the
negative direction. The axis may not be moved again until
the alarm condition is cleared.
motionKernel
3202
0027
World Coordinate System: The command torque was
greater than the allowable range for the axis in the
positive direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.
motionKernel
3202
0028
World Coordinate System: The command torque was
greater than the allowable range for the axis in the
negative direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.
motionKernel
3202
0031
The move specified would exceed the software position
limits in the positive direction and was rejected before
being started. The group may be moved again
immediately if desired.
motionKernel
3202
0032
The move specified would exceed the software position
limits in the negative direction and was rejected before
being started. The group may be moved again
immediately if desired.
motionKernel
3202
0033
The move specified would exceed the software speed
limits in the positive direction and was rejected before
being started. The group may be moved again
immediately if desired.
motionKernel
3202
0034
The move specified would exceed the software speed
limits in the negative direction and was rejected before
being started. The group may be moved again
immediately if desired.
motionKernel
3202
0035
The move specified would exceed the software
acceleration limits in the positive direction and was
rejected before being started. The group may be moved
again immediately if desired.
motionKernel
3202
0036
The move specified would exceed the software
acceleration limits in the negative direction and was
rejected before being started. The group may be moved
again immediately if desired.
motionKernel
3202
0037
The move specified would exceed the software torque
limits in the positive direction and was rejected before
being started. The group may be moved again
immediately if desired.