PLCopenPlus Function Blocks for Motion Control 2013-04-13

259

Notes

Refer to parameters with LREAL Data Type in the

Axis Parameter

List

. Only LREAL type parameters can be read with

Y_ReadMultipleParameters.

Firmware version 2.0.0 and it's YMotion firmware library is required
to use this function block.

PrmStruct.LastPrm is the quantity of parameters to be read, which
will be one less than the last array index value, because the array is
zero based.

BOOL parameters cannot be read with this function block. Use

MC_ReadBoolParameter

.

Error Description

ErrorID

Meaning

0

No Error

4378

The function block is not applicable for the external axis
specified

4402

The scan compensation delay parameter 1305 is only valid for
external encoders.

4403

The High Speed Output functionality is only available on
external encoders.

4625

Axis ID does not correspond to an axis configured on the
system. Verify the value of AxisNum matches a logical axis
number in the configuration. Tip: Make sure AXIS_REF is
properly declared as a VAR or VAR_GLOBAL in all relevant
POUs.

4648

The parameter number does not exist for the specified axis