Yaskawa MotionWorks IEC User Manual
Page 327

PLCopenPlus Function Blocks for Motion Control 2013-04-13
319
app
340C
0204
Unable to reach the network for the EtherNet/IP server.
Common causes include: invalid remote server address,
invalid gateway, invalid subnet mask, or the Ethernet
network is not correctly configured.
app
340C
0205
Remote server rejected connection attempt. The remote
server may not be listening for connections or there may
be a firewall preventing the connection.
app
340C
0206
The Ethernet/IP client ran out of connection slot
resources. Reduce the number of concurrent client
connections.
app
340C
0302
Unable to connect to the Modbus TCP slave. Common
causes include: invalid Modbus TCP slave address, invalid
gateway, invalid subnet mask, or the Ethernet network is
not correctly configured.
app
340C
0303
There is no route to the Modbus TCP slave. Common
causes include: invalid Modbus TCP slave address, invalid
gateway, invalid subnet mask, or the Ethernet network is
not correctly configured.
app
340C
0304
Unable to reach the network for the Modbus TCP slave.
Common causes include: invalid Modbus TCP slave
address, invalid gateway, invalid subnet mask, or the
Ethernet network is not correctly configured.
app
340C
0305
Modbus TCP slave rejected connection attempt. The
Modbus TCP slave may not be listening for connections or
there may be a firewall preventing the connection.
app
340C
0306
The Modbus TCP master ran out of connection slot
resources. Reduce the number of concurrent slave
connections.
app
340C
1020
The controller battery voltage has dropped, indicating it
has failed or is about to fail. While the controller is
powered on, the battery should be replaced as soon as
possible or a prolonged power-down state will cause
various static data to be lost.
app
340C
1028
The driver parameter specified in the axis configuration
caused an exception
app
340C
1029
The driver parameter did not match the axis configuration
app
340C
1030
The configured axis count exceeded the allowable limit.
app
340C
1031
The axis count exceeded the allowable limit due to an
auto-detected axis.
app
340C
1033
Using an incompatible version of the PLCopenPlus
firmware function block library may result in controller
instability. Consequently, the PLC application will not be