Notes, Related function blocks, Error description – Yaskawa MotionWorks IEC User Manual
Page 119

PLCopenPlus Function Blocks for Motion Control 2013-04-13
111
B
Error
BOOL
Set high if error has occurred during the execution of the function
block. This output is cleared when 'Execute' or 'Enable' goes low.
E
ErrorID
UINT
If error is true, this output provides the Error ID. This output is reset
when 'Execute' or 'Enable' goes low.
Notes
• The output 'InVelocity' will be reset when the block is aborted by another
block or at the falling edge of 'Execute'.
• In combination with
, the output 'InVelocity'
stays TRUE once the velocity setpoint of the axis has reached the
commanded velocity.
Related Function Blocks
Jog : Make the axis jog at different speeds without having to re-fire the
execute input bit. Available in the
: Stops an axis in motion by bringing the axis to a standstill state.
Error Description
Meaning
0
No Error
4369
The move could not be buffered because the axis motion
queue is full. 16 moves is the maximum which can be
buffered.
4370
The move could not be started because motion is prohibited.
MC_Stop.Execute might be held high, preventing motion. If
MC_Stop has control of the axis, no other function block can
override the "Stopping" state. Other blocks that try to cause