PLCopenPlus Function Blocks for Motion Control 2013-04-13
304
motionKernel
3103
0100
Controller SRAM battery is low
motionKernel
3103
0101
The file system failed the integral consistency
check. Remedy: Power up the controller in supervisory
mode using the SUP switch. Clear the alarm. Turn off the
SUP switch. Power cycle the controller.
motionKernel
3201
0001
The motion kernel didn't request to enable axis. But, the
axis is enabled.
motionKernel
3201
0002
The motion kernel didn't request to disable axis. But, the
axis is disabled.
motionKernel
3201
0004
The encoder position stored in SRAM could not be
validated. The value has been reset.
motionKernel
3201
0005
Main bus power was disconnected while the axis was
enabled. Main power must be restored and this alarm
cleared before motion can continue.
motionKernel
3201
0101
Configuration error: multiple alarm tasks with duplicate
priority.
motionKernel
3201
0102
Configuration error: Alarm task not configured. Using
default priority and name.
motionKernel
3202
0001
Axis Coordinate System: The command position was
outside the allowable range for the axis in the positive
direction (positive overtravel). The axis may not be moved
again until the alarm condition is cleared. After the alarm
is cleared, it is permissible to execute a move which
brings the axis back toward the allowed region, even
though the axis is probably still outside the allowed
region. Any move which pulls the axis further away from
the allowed region will re-trigger the alarm.
motionKernel
3202
0002
Axis Coordinate System: The command position was
outside the allowable range for the axis in the negative
direction (negative overtravel). The axis may not be
moved again until the alarm condition is cleared. After the
alarm is cleared, it is permissible to execute a move which
brings the axis back toward the allowed region, even
though the axis is probably still outside the allowed
region. Any move which pulls the axis further away from
the allowed region will re-trigger the alarm.
motionKernel
3202
0003
Axis Coordinate System: The command speed was greater
than the allowable range for the axis in the positive
direction (overspeed). The axis may not be moved again
until the alarm condition is cleared.
motionKernel
3202
0004
Axis Coordinate System: The command speed was greater
than the allowable range for the axis in the negative
direction (overspeed). The axis may not be moved again