Yaskawa MotionWorks IEC User Manual
Page 321

PLCopenPlus Function Blocks for Motion Control 2013-04-13
313
limited (default) access.
app
3406
0002
The default login group for the web server was assigned to
a group which did not exist. Access control has been
disabled, because a minimal amount of access is required
in order to log in. The configuration file should be fixed
before continuing.
app
3406
0003
The web server configuration specified access control
should be enabled, but did not specify at least one path to
control access to. Access control has been disabled. The
configuration file should be fixed before continuing.
app
3407
0002
The base directory for configuration files was missing and
has been created automatically. The system has booted in
a minimal configuration mode, and most functionality is
limited. Please upload a new complete configuration file
set.
app
3407
0003
A required default configuration file was missing. A
minimal configuration for the corresponding component
has been loaded, and some functionality may be limited.
app
3407
0004
A required default configuration file was incorrectly
formatted. A minimal configuration for the corresponding
component has been loaded, and some functionality may
be disabled.
app
3407
0005
A configuration file specified by the user configuration file
set was incorrectly formatted. The corresponding default
configuration file is being used instead.
app
3407
0006
The file describing which configuration set to use was
corrupted. The default configuration set is being used.
app
3407
0007
An error occurred while writing a config file. The file
system may be full or damaged.
app
3407
0101
The configured RAM disk on the controller was unable to
be created.
app
3407
0102
Detected an unsupported option card inserted in the
controller.
app
3407
0104
Data in the controller SRAM did not match the expected
value. It should be treated as corrupted until it is re-
initialized.
app
3407
0106
The SRAM battery backup power failed. SRAM data should
be treated as corrupted until it is re-initialized.
app
3407
0107
The controller's time-of-day clock detected a voltage
decrease in the backup battery. The current time and date
is likely to be incorrect. This alarm can be cleared, but will
recur when the controller is powered ON until the time