Yaskawa MotionWorks IEC User Manual
Page 338

PLCopenPlus Function Blocks for Motion Control 2013-04-13
330
Mechatrolink
4312
001E
Reserved
Mechatrolink
4312
001F
Reserved
Mechatrolink
4312
0022
Reserved
Mechatrolink
4312
0023
Reserved
Mechatrolink
4312
0024
Reserved
Mechatrolink
4312
0025
Reserved
Mechatrolink
4312
0026
Reserved
Mechatrolink
4312
0094
Reserved
Mechatrolink
4312
0095
Reserved
Mechatrolink
4312
0096
Reserved
Mechatrolink
4312
00E5
Reserved
app
4401
0008
Each call to groupAxes() must be matched by a
corresponding call to ungroupAxes(). If a script exits
without such a matching call (thus leaving an 'orphaned'
group behind), this warning is issued. Clearing the
warning also ungroups the orphaned group.
app
4401
0009
The debug stack trace was longer than expected. It may
be clipped.
app
4403
0001
The event queue for the remote client was full, and an
event was dropped. This is generally caused either by
exceeding the network bandwidth or exceeding the
general system processing power (starving the
connection). When an event is dropped in this manner,
the connection is terminated.
app
4403
0005
An RMI connection was attempted by an external client
and rejected due to the concurrent connection limit.
app
4407
0001
The configuration file directory is read-only or resides on a
read-only file system. Attempts to update the
configuration or create directories will fail.
app
4407
0002
An attempt was made to write to a read-only configuration
file. The write failed.
app
4407
0105
There was an indication that the SRAM battery backup
power may have failed temporarily. SRAM data may have
been compromised.
app
4408
0001
The alarm history was configured to use NVRAM storage,
but either the available NVRAM was not sufficient to
contain the configured buffer size, or the configured buffer
size was not large enough to contain the configured
number of records. The alarm history will contain fewer
records than configured.
app
4408
0002
The alarm history was configured to use NVRAM storage