beautypg.com

4 units—centr ic dr illing – HEIDENHAIN SW 548328-05 DIN Programming User Manual

Page 79

background image

HEIDENHAIN MANUALplus 620, CNC PILOT 620/640

79

2.4 Units—Centr

ic dr

illing

CLT

Coolant

0: Without

1: Circuit 1 on

2: Circuit 2 on

SCK

Safety clearance in infeed direction: Safety clearance in

infeed direction during drilling and milling operations.

G60

Protection zone. During drilling and boring the protection

zone monitoring is

0: Active

1: Inactive

BP

Break duration: Time span for interruption of the feed for

chip breaking.

BF

Feed duration: Time interval until the next break. The

interruption of the feed rate breaks the chip.

Further forms:

see page 58

If X is not programmed or XS is in the range of –2 mm < XS

< 2 mm, then the MANUALplus drills at XS.