The Global form
This form contains parameters that were defined as default values in

the start unit. You can edit these parameters in the machining units.
Parameters on the Global form

G14

Tool change point

No axis

0: Simultaneously

1: First X, then Z

2: First Z, then X

3: Only X

4: Only Z

5: Y direction only

6: Simultaneous with Y (X, Y and Z axes move on a

diagonal path)

CLT

Coolant

0: Without

1: Circuit 1 on

2: Circuit 2 on

G47

Safety clearance: Indicates the distance to the current blank

material at which the tool is not moved at rapid traverse.

SCK

Safety clearance in infeed direction: Safety clearance in

infeed direction during drilling and milling operations.

SCI

Safety clearance in plane: Safety clearance in the working

plane during drilling and milling operations.

G60

Protection zone. During drilling and boring the protection

zone monitoring is

0: Active

1: Inactive