1 smar t.t u rn units – HEIDENHAIN SW 548328-05 DIN Programming User Manual
Page 62

62
smart.Turn units
2.1 smar
t.T
u
rn
units
The Global form
This form contains parameters that were defined as default values in
the start unit. You can edit these parameters in the machining units.
Parameters on the Global form
G14
Tool change point
No axis
0: Simultaneously
1: First X, then Z
2: First Z, then X
3: Only X
4: Only Z
5: Y direction only
6: Simultaneous with Y (X, Y and Z axes move on a
diagonal path)
CLT
Coolant
0: Without
1: Circuit 1 on
2: Circuit 2 on
G47
Safety clearance: Indicates the distance to the current blank
material at which the tool is not moved at rapid traverse.
SCK
Safety clearance in infeed direction: Safety clearance in
infeed direction during drilling and milling operations.
SCI
Safety clearance in plane: Safety clearance in the working
plane during drilling and milling operations.
G60
Protection zone. During drilling and boring the protection
zone monitoring is
0: Active
1: Inactive