Touch probe cycles

5.8 Measur

e angle

Misalignment compensation after angle
measurement G788

Cycle G788 activates a misalignment compensation determined with

Cycle G787 Angle Measurement.

Example: G788 Misalignment compensation after
angle measurement

. . .

MACHINING

N3 G788 NF1 P0

. . .

Parameters

NF Result variable no.: Number of the first global variable in which

the result is saved (no entry = variable 810). The second

measurement result is saved automatically under the next

consecutive number.

P

Compensation

0: OFF: Do not perform misalignment compensation

1: ON: Perform misalignment compensation