beautypg.com

2 touch probe cycles for single- point measurement, 2 touch probe cycles for single-point measurement – HEIDENHAIN SW 548328-05 DIN Programming User Manual

Page 433

background image

HEIDENHAIN MANUALplus 620, CNC PILOT 620/640

433

5.2 T

o

uc

h pr

obe cy

cles f

or single-point measur

ement

5.2

Touch probe cycles for single-
point measurement

Single-point measurement for tool
compensation G770

Cycle G770 measures with the programmed measuring axis in the

specified direction. If the tolerance value defined in the cycle is

exceeded, the cycle saves the measured deviation either as tool

compensation or as an additive compensation. The result of the

measurement is saved additionally in the variable #i99 (See "Touch

probe cycles for automatic operation" on page 431.).

Cycle run
From the current position the touch probe moves along the defined

measuring axis toward the measuring point. When the stylus touches

the workpiece, the measured value is saved and the touch probe is

positioned back to the starting point.
The control outputs an error message if the touch probe does not

reach any touch point within the defined measuring path. If a

maximum deviation WE was programmed, the measuring point is

approached twice and the mean value is saved as result. If the

difference of the measurements is greater than the maximum

deviation WE, the program run is interrupted and an error message is

displayed.

Example: G770—Single-point measurement for
tool compensation

. . .

MACHINING

N3 G770 R1 D0 K20 AC0 BD0.2 WT3 V1 O1 Q0
P0 H0

. . .

Parameters

R

Type of compensation:

1: Tool compensation DX/DZ for turning tool or additive

compensation

2: Recessing tool Dx/DS

4: Milling tool DD

D

Measuring axis: Axis in which the measurement is to be made

K

Incremental measuring path with direction (signed): Maximum

measuring path for probing. The algebraic sign determines the

probing direction.

AC Nominal value for target position: Touch point coordinate
BD Tolerance +/-: Measurement result range in which no

compensation is applied

WT Compensation number T or G149:

T

: Tool at turret position T to compensate the difference to

the nominal value

G149

: Additive compensation D9xx to correct the difference to

the nominal value (only possible with compensation type R =1)

E

Maximum compensation value for the tool compensation

WE Maximum deviation: Probe twice and monitor the dispersion of

the measured values