4 cont our f o rm elements – HEIDENHAIN SW 548328-05 DIN Programming User Manual
Page 206

206
DIN programming
4.4 Cont
our f
o
rm
elements
Undercut DIN 509 E (H=0.5)
The Control uses the diameter to calculate the parameters that you do
not define.
Undercut DIN 509 F (H=6)
The Control uses the diameter to calculate the parameters that you do
not define.
Example: Call G25-Geo DIN 509 E
. . .
N.. G1 Z-15 [longitudinal element]
N.. G25 H5 [DIN 509 E]
N.. G1 X20 [transverse element]
. . .
Parameters
H
Undercut type DIN 509 E: H=0 or H=5
I
Undercut depth (radius)
K
Width of undercut
R
Undercut radius (in both corners of the undercut)
W Undercut angle
BE, BF, BD, BP and BH (see "Machining attributes for form elements"
Example: Call G25-Geo DIN 509 F
. . .
N.. G1 Z-15 [longitudinal element]
N.. G25 H6 [DIN 509 F]
N.. G1 X20 [transverse element]
. . .
Parameters
H
Undercut type DIN 509 F: H=6
I
Undercut depth (radius)
K
Width of undercut
R
Undercut radius (in both corners of the undercut)
P
Face depth
W Undercut angle
A
Transverse angle
BE, BF, BD, BP and BH (see "Machining attributes for form elements"