beautypg.com

Find stud in c lateral surface g783, 6 sear c h cy cles – HEIDENHAIN SW 548328-05 DIN Programming User Manual

Page 464

background image

464

Touch probe cycles

5.6 Sear

c

h

cy

cles

Find stud in C lateral surface G783

Cycle G783 probes the workpiece face several times with the X axis.

Prior to each probing, the touch probe is shifted by a distance defined

in the cycle until a stud is found. Optionally, the cycle determines the

mean value by two probing operations on the stud diameter.
If the tolerance value defined in the cycle is exceeded, the cycle saves

the measured deviation as zero point shift. The result of the

measurement is saved additionally in the variable #i99.

Cycle run
From the current position the touch probe moves along the measuring

axis Z toward the measuring point. When the stylus touches the

workpiece, the measured value is saved and the touch probe is

positioned back to the starting point. Then the cycle rotates the C axis

by the angle defined in the Search Grid parameter RC and probes again

with the Z axis. This process is repeated until a stud is found. The cycle

performs two probing operations on the stud diameter with the C axis,

calculates the center of the hole and places the zero point in the C axis.
The control outputs an error message if the touch probe does not

reach any touch point within the defined measuring path. If a

maximum deviation WE was programmed, the measuring point is

approached twice and the mean value is saved as result. If the

difference of the measurements is greater than the maximum

deviation WE, the program run is interrupted and an error message is

displayed.

Example: G783 Find stud in C lateral surface

. . .

MACHINING

N3 G783 R1 D1 K2 C0 RC10 IC20 AC0 BD0.2 Q0
P0 H0

. . .

Result #i99

Meaning

< 999997

Result of first measurement

999999

Deviation of probing operations was higher than

programmed in Maximum Deviation parameter WE.

Parameters

R

Type of zero point shift:

1: Activate table and G152 zero point shift and additionally

save in zero point table. The zero-point shift also remains

active after the program run.

2: Activate zero point shift with G152 for the further program

run. Zero point shift no longer active after program run.

D

Result:

1: Position: Set zero point without determining the stud

center. The stud diameter is not probed.

2: Object center: Before the zero point is set, determine stud

center in two probing operations with the C axis.

K

Incremental measuring path Z (signed): Maximum measuring

path for probing. The algebraic sign determines the probing

direction.

C

Starting position C: Position of the C axis for the first probing

operation

RC Search grid Ci: Stepping angle of the C axis for the subsequent

probing operations

A

Number of points: Maximum number of probing operations