246

DIN programming

4.1

1

F

eed r

a

te

, shaf

t speed

4.11 Feed rate, shaft speed

Speed limitation G26

G26: Main spindle; Gx26: Spindle x (x: 1...3)

The speed limitation remains in effect until the end of the program or

until a new value is programmed for G26/Gx26.

Interrupted feed G64

G64 interrupts the programmed feed for a short period of time. G64 is

a modal function.

For switch-on, program G64 with E and F.

For switch-off, program G64 without parameters.

Example: G26

. . .

N1 G14 Q0

N1 G26 S2000 [maximum speed]

N2 T3 G95 F0.25 G96 S200 M3

N3 G0 X0 Z2

. . .

Parameter

S

(Maximum) speed

If S > "absolute maximum speed" (machine parameter),

the parameter value will apply.

Example: G64

. . .

N1 T3 G95 F0.25 G96 S200 M3

N2 G64 E0.1 F1 [interrupted feed on]

N3 G0 X0 Z2

N4 G42

N5 G1 Z0

N6 G1 X20 B-0.5

N7 G1 Z-12

N8 G1 Z-24 A20

N9 G1 X48 B6

N10 G1 Z-52 B8

N11 G1 X80 B4 E0.08

N12 G1 Z-60

N13 G1 X82 G40

N14 G64 [interrupted feed off]

. . .

Parameters

E

Pause duration (0.01 s < E < 99.99 s)

F

Feed duration (0.01 s < E < 99.99 s)