beautypg.com

Two-point measurement g18 longitudinal g776 – HEIDENHAIN SW 548328-05 DIN Programming User Manual

Page 443

background image

HEIDENHAIN MANUALplus 620, CNC PILOT 620/640

443

5.3 T

o

uc

h pr

obe cy

cles f

o

r tw

o-point measur

ement

Two-point measurement G18 longitudinal G776

Cycle G776 measures two opposite points in the X/Z plane with the
measuring axis Z

. If the tolerance values defined in the cycle are

exceeded, the cycle saves the measured deviation either as tool

compensation or as an additive compensation. The result of the

measurement is saved additionally in the variable #i99 (See "Touch

probe cycles for automatic operation" on page 431.).

Cycle run
From the current position the touch probe moves along the defined

measuring axis toward the measuring point. When the stylus touches

the workpiece, the measured value is saved and the touch probe is

positioned back to the starting point. For the pre-positioning for the

second measurement, the cycle first moves the touch probe by the

offset in the circumnavigation direction RB and then by the offset in the

measuring direction RC. The cycle executes the second probing

operation in the opposite direction, saves the result and positions the

touch probe with the circumnavigation axis by the circumnavigation

value.
The control outputs an error message if the touch probe does not

reach any touch point within the defined measuring path. If a

maximum deviation WE was programmed, the measuring points are

approached twice and the mean value is saved as result. If the

difference of the measurements is greater than the maximum

deviation WE, the program run is interrupted and an error message is

displayed.

Example: G776—Two-point measurement for tool
compensation

. . .

MACHINING

N3 G775 R1 K20 E1 XE30 BD0.2 X40 BE0.3
WT5 Q0 P0 H0

. . .

Parameters

R

Type of compensation:

1: Tool compensation DX/DZ for turning tool or additive

compensation

2: Recessing tool Dx/DS

3: Cutter DX/DD

4: Milling cutter DD

K

Incremental measuring path with direction (signed): Maximum

measuring path for probing. The algebraic sign determines the

probing direction.

E

Circumnavigation axis: Selection of axis for retraction

movement between the probing positions:

0: X axis

2: Y axis

RB Circumnavigation direction offset: Distance
RC Offset Z: Distance for pre-positioning before the second

measurement

ZE Nominal value for target position Z: Absolute coordinate of touch

point

BD Tolerance +/-: Range for the first measurement result in which

no compensation is applied

Z

Nominal width Z: Coordinate for the second probing position

BE Tolerance width +/-: Range for the second measurement result

in which no compensation is applied