beautypg.com

Zero point c axis, single-point measurement g772 – HEIDENHAIN SW 548328-05 DIN Programming User Manual

Page 437

background image

HEIDENHAIN MANUALplus 620, CNC PILOT 620/640

437

5.2 T

o

uc

h pr

obe cy

cles f

or single-point measur

ement

Zero point C axis, single-point measurement
G772

Cycle G772 measures with the C axis in the specified direction. If the

tolerance value defined in the cycle is exceeded, the cycle saves the

measured deviation as zero point shift. The result of the measurement

is saved additionally in the variable #i99 (See "Touch probe cycles for

automatic operation" on page 431.).

Cycle run
From the current position, the element to be probed is moved toward

the touch probe by a rotation of the C axis. When the workpiece

touches the stylus, the measured value is saved and the workpiece is

returned.
The control outputs an error message if the touch probe does not

reach any touch point within the defined measuring path. If a

maximum deviation WE was programmed, the measuring point is

approached twice and the mean value is saved as result. If the

difference of the measurements is greater than the maximum

deviation WE, the program run is interrupted and an error message is

displayed.

Example: G772—Single-point measurement zero
point C axis

. . .

MACHINING

N3 G772 R1 C20 AC0 BD0.2 Q0 P0 H0

. . .

Parameters

R

Type of zero point shift:

1: Table and G152: Activate zero point shift and additionally

save in zero point table. The zero-point shift also remains

active after the program run.

2: Activate zero point shift with G152 for the further program

run. Zero point shift no longer active after program run.

C

Incremental measuring path with direction: Measuring path of

the C axis (in degrees), starting from the current position. The

algebraic sign determines the probing direction.

AC Nominal value for target position: Absolute coordinate of touch

point in degrees

BD Tolerance +/-: Measurement result range (in degrees) in which

no compensation is applied

KC Compensation offset: Additional compensation value that is

applied to the zero point result

WE Maximum deviation: Probe twice and monitor the dispersion of

the measured values

F

Measuring feed rate: Feed rate for probing. If nothing is entered,

the measuring feed rate from the touch probe table is used. If

the entered measuring feed rate F is higher than the one in the

touch probe table, the feed rate is reduced to the value from the

touch probe table.