DIN programming

4.4 Cont

our f

o

rm

elements

Undercut type K (H=9)

Example: Call G25-Geo type K

. . .

N.. G1 Z-15 [longitudinal element]

N.. G25 H9 I1 R0.8 W40 [type K]

N.. G1 X20 [transverse element]

. . .

Parameters

H

Undercut type K: H=9

I

Undercut depth

R

Undercut radius—no value: The circular element is not

machined

W Undercut angle
A

Angle to longitudinal axis (default: 45°)

BE, BF, BD, BP and BH (see "Machining attributes for form elements"

on page 195)