beautypg.com

Properties, Results – Adept AdeptSight User Guide User Manual

Page 532

background image

Properties

Properties

Object

Definition

Port Number

The TCP/IP port used to communicate with the
Remote Vision Server.

Vision Server IP Address

The IP address of the Remote Vision Server run-
ning the vision tool.

Time Out

The maximum time duration (in milliseconds)
allowed for the remote operation to complete.

Remote Tool Name

The name of the vision tool to be activated
remotely.

Remote Vision Tool Object Editor

Results

Object

Definition

Instance

The index of the located instance.

Position X

The X coordinate of the located instance.

Position Y

The Y coordinate of the located instance.

Angle

The angle of the located instance.

Model Name

Name of the model located.

The AdeptSight PC can run multiple instances of the Remote Vision tool, offloading multiple
vision tools to a remote PC. The remote PC returns the results of the vision tool to the Adept-
Sight PC.

Offloading the image processing to a remote PC allows a single instance of AdeptSight, on the
main PC, to manage larger AdeptSight applications.

l

The AdeptSight PC is the main PC; it runs the AdeptSight application. This is required
for all AdeptSight installations.

l

The Remote Vision Server is an optional, secondary PC, used to off-load processing of
vision tools.

o

The Remote Vision Server is passive: it waits for a request from the AdeptSight
application to run a vision tool.

o

The Remote Vision Server requires a separate USB dongle to run vision tools.

o

Any tool that can be run on the AdeptSight PC can be run on the Remote Vision

AdeptSight User's Guide, Version 3.2.x, Updated: 8/23/2012