Related topics – Adept AdeptSight User Guide User Manual
Page 272
Related Topics
Object
Definition
Custom
Custom Sampling Step lets you set a sampling
step value other than the default. To select a cus-
tom sampling step, Enable must be checked.
l
Increasing the sampling step value reduces
the tool accuracy and decreases the
execution time.
l
Reducing the sampling step can increase
the tool accuracy but will also increase the
execution time.
Edge Filter Half-Width
The filtering process attenuates peaks in the magnitude curve that are caused by noise. Filter
Half-Width should be set to a value approximately equivalent to the width of the edge, in pix-
els, as it appears in the image. An incorrect value can cause edges to be incorrectly detected.
Projection Mode
Projection mode used by the tool to detect edges. Projection mode is either radial or annular.
Sort Results Enabled
When Sort Results Enabled is set to false (default) edges are sorted in order of their location
within the region of interest. When true, edges are sorted in the order of their score, from
highest to lowest.
Results Logging
If enabled, the results of the tool will be logged to a file.
If the extension of the destination file is csv, then the log is written in csv format, which
opens with Excel. If a different extension is selected, the log is written in a plain text format
(similar to the AdeptSight 2 format).
The size of the log file can be set (default size is 5 Mb).
Related Topics
Configuring Arc Edge Locator Properties on page 263
Arc Edge Locator Results on page 273
AdeptSight User's Guide, Version 3.2.x, Updated: 8/23/2012
Page 272