Take a Picture of the Calibration Target

Located Calibration Target

1. Place the target near the upstream limit, within the work area.

2. Adjust the bounding box to the work area. This must include the calibration tar-

get.

3. If the target isn't marked with a magenta origin, click Run.

If necessary, move the target so it can be located, then click Run.

l

Advance the Belt

NOTE: The belt will be advanced four times in this procedure. Advance the belt so
that the target moves less than a quarter of the total distance from point 1 to the
downstream limit.

Do not touch the target.

l

Teach the Robot Position at Object 1

AdeptSight Camera Calibration Wizard - Manual with Belt

AdeptSight User's Guide, Version 3.2.x, Updated: 8/23/2012