8.3 Site Configuration

The controller allows configuration of other options that can be accessed through the menu option
Configuration → Controller Config
(as shown in Figure 7-2).

8.3.1 Site Name

The controller site name defaults to “RET1 ASCU” but can be modified at any time. This identifier is
not usually important unless the controller is one of many nodes managed by network management
software such as Andrew’s Site Manager.

8.3.2 External Bus Power (ATC300-1000/2000 only)

By default, the ATC300-1000/2000 limits the number of ALD devices in its database to 32 due to power
requirements. However, if the devices are externally powered, this option may be selected to expand
that limit to 64 ALD devices.

8.3.3 Alarm Relay Configuration (ATC300-1000/2000 only)

The alarm relays on the ATC300-1000/2000 are “normally open” by default. This option changes that
logic and treats the relays as “normally closed”.

Note that after changing this configuration, the controller may need to be rebooted for the relays to
reflect the current alarm states correctly.