beautypg.com

CommScope ATC300-2000 User Manual

Page 56

background image

ATC300-1000/2000 Teletilt

®

RET System

Section 5–Obtaining IP Settings for Controller (When IP is Unknown)

Bulletin 639544 • Revision L

August 2014

5-7

5.2 Determining the IP settings on an ATC200-1000
5.2.1 Establishing a Serial Connection to the Controller

1. Ensure that the controller is powered up. On power up, the status LED will first be steady red and

then blink red until it becomes a solid red or green. After the LED is a solid color for 20 seconds,
it is ready to be connected to a COM1 serial port of a computer.

2. Using an RS–232 serial cable, connect the COM1 serial port on a local computer and the LMT

serial port on the front of the controller (Figure 5-11).

Microsoft, Encarta, MSN, and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States
and/or other countries.

3. Go

to

Control Panel, Network Connection, New Connection Wizard (Figures 5-12 and 5-13).

Windows® 2000 users, see paragraph 5.2.3 (screens not shown).

Double click on the

Network Connections icon.

Figure 5-11. Local PC Connected To Controller’s LMT Serial Port Using An RS–232 Cable.

Figure 5-12. Nework Connection Icon

RS-232 Serial Cable

LMT

Serial Port

Ethernet

Port

This manual is related to the following products: