Appendix D–Relay Alarms

ATC300-1000/2000 Teletilt

®

RET System

D-2

August 2014

Bulletin 639544 • Revision L

Meaning

AISG1.0/1.1

AISG 2.0

Actuator Detection Fail

Signals from the actuator are detected but are ab-
normal or corrupted.

Actuator Jam Permanent

Actuator cannot be moved.

Actuator Jam Temporary

Actuator jam has been detected. No movement
was temporarily detected in response to the normal
stimulus.

Motor Jam

Motor cannot move.

ActuatorJam

Actuator jam has been detected. No movement
of the actuator, but movement of the motor was
detected.

EEPROM Error

EEPROM error detected

Flash Erase Error

Used in combination with software download. Indi-
cates error when erasing flash memory.

Not Calibrated

The device has not completed a calibration opera-
tion, or calibration has been lost.

Not Scaled

No setup table has been stored in the device.

Not Configured

Actuator configuration data is missing.

Other Hardware Error

Any hardware error which cannot be classified.

Hardware Error

Any hardware error which cannot be classified. May
not be reported as an alarm until the fault is likely to
be persistent.

Other Software Error

Any software error which cannot be classified.

Position Lost

RET controller is unable to return a correct position
value. For example, there was a power failure while
a Set Tilt command was being executed.

RAM Error

An error was detected in reading data to/from RAM.

UART Error

Hardware specific. This error may be sent after re-
covery from a temporary error which has prevented
the sending or receiving of data.

TMA Alarm Minor

An event has taken place that effects the TMA per-
formance, the TMA continues to function, and by-
pass is not implemented. (The actual performance
degradation criteria must be vendor specified.)

TMA Alarm Major

An event has taken place that renders TMA perfor-
mance unacceptable. If bypass is fitted, the TMA
will switch into bypass.

Bypass Mode

A TMA band is set to bypass mode.

Actuator Interference

An actuator movement outside the control of the
RET unit has been detected. Probable cause is
manual interference.

Table D-1. Relay Alarm Definitions.