Appendix D–Relay Alarms
ATC300-1000/2000 Teletilt
®
RET System
D-2
August 2014
Bulletin 639544 • Revision L
Meaning
AISG1.0/1.1
AISG 2.0
Actuator Detection Fail
Signals from the actuator are detected but are ab-
normal or corrupted.
Actuator Jam Permanent
Actuator cannot be moved.
Actuator Jam Temporary
Actuator jam has been detected. No movement
was temporarily detected in response to the normal
stimulus.
Motor Jam
Motor cannot move.
ActuatorJam
Actuator jam has been detected. No movement
of the actuator, but movement of the motor was
detected.
EEPROM Error
EEPROM error detected
Flash Erase Error
Used in combination with software download. Indi-
cates error when erasing flash memory.
Not Calibrated
The device has not completed a calibration opera-
tion, or calibration has been lost.
Not Scaled
No setup table has been stored in the device.
Not Configured
Actuator configuration data is missing.
Other Hardware Error
Any hardware error which cannot be classified.
Hardware Error
Any hardware error which cannot be classified. May
not be reported as an alarm until the fault is likely to
be persistent.
Other Software Error
Any software error which cannot be classified.
Position Lost
RET controller is unable to return a correct position
value. For example, there was a power failure while
a Set Tilt command was being executed.
RAM Error
An error was detected in reading data to/from RAM.
UART Error
Hardware specific. This error may be sent after re-
covery from a temporary error which has prevented
the sending or receiving of data.
TMA Alarm Minor
An event has taken place that effects the TMA per-
formance, the TMA continues to function, and by-
pass is not implemented. (The actual performance
degradation criteria must be vendor specified.)
TMA Alarm Major
An event has taken place that renders TMA perfor-
mance unacceptable. If bypass is fitted, the TMA
will switch into bypass.
Bypass Mode
A TMA band is set to bypass mode.
Actuator Interference
An actuator movement outside the control of the
RET unit has been detected. Probable cause is
manual interference.
Table D-1. Relay Alarm Definitions.