Section 15–Device Configuration-Multiple Integrated Actuators

ATC300-1000/2000 Teletilt

®

RET System

15-2

August 2014

Bulletin 639544 • Revision L

Notice that the ID for the device that was selected from the main screen appears in the title bar of the
Device Configuration screen. Required fields are marked with an asterisk. Saving a new configura-
tion will not be permitted if any of the required fields are left blank or if values are out of range. Refer
to Figure 15-2.

2. Factory installed actuators are pre-configured to include the antenna model number, antenna type,

and antenna serial number it is operating.

3. MRET antennas do not allow re-configuring these fields.

4. Specify the parameters for the remaining fields (Frequency Band, Technology, Base Station ID,

Installer ID, Installation Date, Mechanical Tilt, Bearing, Height, Sector, Location).

Note the following:

• The fields of Antenna Type, Technology, Location, and Height are available for Andrew

non-TMA devices only.

• A positive mechanical tilt angle means that the antenna beam is directed below the

horizontal plane. A negative mechanical tilt angle means that the antenna beam is

directed above the horizontal plane.

The

Bearing is the installed compass orientation for this antenna.

The

Height of the antenna up the tower must be entered in the range of 1 to 999. No specif-

ic unit of length, such as feet or meters, is associated with this field. However, you should

enter a value that conforms to the units of length customarily used by your company for

antenna

installations.

Figure 15-2. Configuring A New Device.

Fields marked with an
asterisk must be configured.

2. Click on Set Device Data.

1. Make appropriate selections and

text entries. (All configuration data is
stored in the individual device.)

RET device ID shown.

This manual is related to the following products: