CommScope ATC300-2000 User Manual
Page 74
ATC300-1000/2000 Teletilt
®
RET System Section 7–Changing the Controller’s IP Settings for Access Over a Network
Bulletin 639544 • Revision L
August 2014
7-3
7.1.1 Configuring the Controller to Use A Static IP Address
The new IP settings should be noted and retained before the settings are applied to the controller.
Settings in the controller Config window (Figure 7-3) determine if a site’s network is accessed using
a static IP address or DHCP.
Note: DHCP is not an option on the ATC200-1000.
1. Enter the static IP address provided by the Network Administrator for the controller to operate over
the network system (Figure 7-3).
2. Ensure
the
Use DHCP box is not checked ( ACT300-1000/2000 only ).
3. Enter
a
Network Mask.
4. Click
on
Set IP Details. Answer OK when the Proceed dialog appears (Figure 7-5).
5. Click
on
Reboot. The connection between the local computer and the controller will be lost upon
reboot.
6. Restore the local computer’s IP address to its network compatible settings (see Sections 3 and 4). If
the Andrew IP Config Tool was used to configure the local computer’s IP settings, the original IP set-
tings will be restored to the computer when the application tool is closed (see Section 3 for details).
• Type the controller’s new network configured IP address into the URL address window,
and click on Go.
Figure 7-3. Configuring Controller’s Static IP Address For Access Over a Network.
2. Use DHCP is
not
checked.
3. Enter Controller’s Network Mask.
1. Enter Controller’s Static IP Address.
4. Click Set IP Details.
5. Click to Reboot.