2 updating aisg device firmware – CommScope ATC300-2000 User Manual
Page 103
Section 10–Uploading Device Firmware
ATC300-1000/2000 Teletilt
®
RET System
10-2
August 2014
Bulletin 639544 • Revision L
Figure 10-2. ATC300-1000/2000 Controller Device Search Screen.
Click on Start Scan.
2. Click on the Start Scan button (Figure 10-2). The Device Search Progress window shows when
the device search locates each device connected to the RET system.
10.2 Updating AISG Device Firmware
Operators can easily see the Update Required state of each device scanned on a RET system (Figure
10-3). The ATC300-1000/2000 controller shows each device in one of the following states:
• A
dashed line indicates a device that cannot be upgraded or that must be upgraded manually.
See Appendix C.
•
Unknown indicates that no firmware for that device has been installed on the controller.
•
Yes or No means the device does or does not require an upgrade to the latest device firmware.
1. When the device scan is complete, the Update Req’d field will display the current firmware status
for each device. Figure 10-3 shows one TMA and three actuators that require updates.
2. Click
on
Update Devices (Figure 10-3).
3. Only the devices in need of updates will appear on the Device Upgrades Recommended screen
(Figure 10-4). Some devices may take longer to update as noted in the Approx. Upgrade Time
field.
4. Click on the Install Firmware button (Figure 10-4).