Accessing the Controller Using a Direct
Ethernet Connection
6.0 Section Overview
The ATC300-1000/2000 and ATC300-1000/2000 controller is equipped with an Ethernet port that can
be accessed directly from a local computer using an Ethernet cable (supplied).
6.1 Using an Ethernet Cable for Establishing a Direct Connection from
a Local Computer to the Controller
1. Connect the controller to the local computer using the crossover Ethernet cable provided and ensure
controller is powered up (Figure 6-1). Power cycle controller if it was previously on a network.
Note: Because the ATC300-1000/2000 controller is auto-sensing, a straight-through Ethernet
cable may be used instead.
Figure 6-1. Local PC Connected To Controller’s Ethernet Port Using An Ethernet Cable.
Figure 6-2. Entering Controller’s IP Address Into Internet Browser.
1. Type controller’s IP address into
Internet browser URL window.
2. Click on Go (or press
Enter on the keyboard).
LMT
Serial Port
Ethernet
Port
Ethernet Cable
2. If the IP setting on the local computer is not already configured to communicate with the controller,
refer to Sections 3 and 4.
3. Open an Internet browser (Netscape and Mozilla browsers are not supported). If the controller’s
interface does not automatically appear, type the controller’s Ethernet IP address into the URL
address window, and click on Go (Figure 6-2).